Lighting Assessment

Turn your building’s light into a case your board can defend.

Independent experts measure the light your occupants actually live under, then translate it into the financial language that survives value engineering. We don’t sell fixtures. The assessment shows exactly where your light falls short; the next step puts a number on what that’s costing you.

Sample readout

Generated sample data

Waiting area by the window

#36 · Waiting area · Level 2

664lx mEDI

250 or more

Waiting area by the window: 664 lux melanopic EDI, 250+ mEDI, meets daytime target. Across the building, 20 of 48 positions are below the 250 lux daytime target.

Sample spectrumMelanopic sensitivity (CIE S 026)
400500600700nm
Explore every position on the plan ↓

Why Earthlight

Independent lighting experts, translating research into financial intelligence

Experienced

Over a decade translating circadian lighting science into the financial language that owners, operators, and boards actually use to decide.

Research-backed

Our models are built on the most credible peer-reviewed lighting science and the recognized measurement standards the field has converged on.

Product-neutral

We're paid for the analysis, not the fixtures. The assessment is finished before any vendor is in the room, and when we help you source against it, a proposal clears on the performance it delivers, whoever it comes from.

The engagement

One visit, an evidence-grade baseline

Everything downstream (the comparison report, the pilot, the purchase) is built on this measurement. Experts on site, documenting the light your building actually delivers, in the same units the standards are written in.

The visit

Light Environment Assessment

An on-site visit. We document your building's actual light: lux levels, color temperature, spectra, the timing of light exposure across the occupied day, and the quality of darkness at night. We map circadian-disruption risk area by area, population by population.

You receive a written summary of where the building stands, in language your architect, clinical lead, and facilities team can all read.

What you receive

  • Current lux levels and spectral readingsSee sample ↓
  • Timing of light exposure across the occupied day
  • Darkness quality at night
  • Circadian-disruption risk mapped by area and populationSee sample ↓
  • Written summary for architect, clinical, and facilities teamsSee sample ↓

What that looks like

The deliverables, shown on a sample building

Everything tagged Generated sample data below is from our sample report for Kestrel Medical Centre, an invented 3-floor outpatient clinic with generated readings at 48 positions, laid out as one morning’s walk-through. Client reports stay confidential, so this is the one we show.

01

Current lux levels and spectral readings

Every position, on the plan

Generated sample data

Select a point to see what the meter recorded there.

0510 mN15
  • Below 125
  • 125 to 250
  • 250 or more
  • Hollow: daylight-dominated
  • Glazing
  • Direction the meter faced

mEDI in lx. North wall is a party wall; glazing on the south, west and east.

Reading 15 of 48

Exam room G.3

Clinician's desk against the back wall

Surveyor’s note. In a real assessment, the site photo taken with the reading sits beside it.

Melanopic EDI

125 to 250 mEDI

174lx

125250log scale
Illuminance
352 lx
Melanopic DER
0.49
Colour temperature
3,477 K
CRI Ra / R9
80 / -38
TM-30 Rf / Rg
80 / 96
Daylight share
0%

Fluorescent (tri-phosphor) · Fluorescent 3500 K · Ground floor · 09:39

Sample spectrumMelanopic sensitivity (CIE S 026)
400500600700nm

Hover, tap or use the arrow keys on the chart to read any wavelength.

48 positions across 20 zones, 08:45 to 11:51. Each point is one reading at eye level: what the meter faced, the light it recorded, and that light's spectrum against the melanopic curve.

All 48 positions against 125 and 250

Generated sample data

Melanopic EDI (lx), log scale · reading number, in survey order

505001k2k250125GroundL1L2targetWELL112243648
  • Below 125 mEDI
  • 125 to 250 mEDI
  • 250+ mEDI, meets daytime target
  • Hollow: daylight-dominated
Melanopic EDI at each position in the order it was taken. 28 of 48 reach the 250 lx daytime target; 9 of the 9 daylight-dominated positions do.

Colour temperature and circadian signal per lux

Generated sample data
3,0004,0005,0006,0000.40.50.60.70.80.9Melanopic DER (mEDI per lux)Colour temperature (K)LED 2700 KFluorescent 3500 KLED 4000 KDaylight-dominated

Illuminance needed at the eye to reach 250 lx melanopic EDI, at each source’s median DER

  • LED 2700 KDER 0.40620 lx
  • Fluorescent 3500 KDER 0.50500 lx
  • LED 4000 KDER 0.56450 lx
  • Daylight-dominatedDER 0.82300 lx

Unlabelled points mix electric light and daylight. Shapes show each reading’s mEDI band, as on the map.

Melanopic DER is melanopic EDI per lux. The lower it is, the more light a source needs to deliver the same circadian signal, which is why an illuminance reading alone can look adequate and still fall short.

Old fittings and new

Generated sample data
  • LED 2700 K

    Level 1 · 2 positions

    64 lx mEDI
    at 160 lx · DER 0.40

  • Fluorescent 3500 K

    Original fit-out · Ground floor, Level 1 · 7 positions

    111 lx mEDI
    at 224 lx · DER 0.50

  • LED 4000 K

    Refurbished fit-out · Level 2 · 3 positions

    196 lx mEDI
    at 351 lx · DER 0.56

Melanopic EDI (lx), linear · lines at 125 and 250 · bar: median

Positions lit by electric light alone, by installed source.

What lit each position

Generated sample data
Each reading classified by its daylight share: daylight-dominated at 60% or more, electric light alone under 5%.

02

Timing of light exposure across the occupied day

Not in this sample: it is a single morning walk-through, with no readings later in the day or after dark.

03

Darkness quality at night

Not in this sample: it is a single morning walk-through, with no readings later in the day or after dark.

04

Circadian-disruption risk mapped by area and population

Median melanopic EDI, zone by zone

Generated sample data

Ground floor

  • Procedure room535 lux median melanopic EDI, 3 readings
  • Exam room G.1340 lux median melanopic EDI, 2 readings
  • Exam room G.2336 lux median melanopic EDI, 2 readings
  • Reception & waiting200 lux median melanopic EDI, 4 readings
  • Exam room G.3184 lux median melanopic EDI, 2 readings
  • Records & storage105 lux median melanopic EDI, 2 readings
  • Ground corridor96 lux median melanopic EDI, 2 readings

Level 1

  • Admin office, window side804 lux median melanopic EDI, 4 readings
  • Consult room 1.1395 lux median melanopic EDI, 2 readings
  • Consult room 1.2342 lux median melanopic EDI, 2 readings
  • Level 1 corridor214 lux median melanopic EDI, 2 readings
  • Admin office, core side132 lux median melanopic EDI, 4 readings
  • Staff break room64 lux median melanopic EDI, 2 readings

Level 2

  • Nurse station882 lux median melanopic EDI, 2 readings
  • Waiting area664 lux median melanopic EDI, 3 readings
  • Exam room 2.1568 lux median melanopic EDI, 2 readings
  • Exam room 2.2528 lux median melanopic EDI, 2 readings
  • Consult room 2.1262 lux median melanopic EDI, 2 readings
  • Exam room 2.3208 lux median melanopic EDI, 2 readings
  • Level 2 corridor117 lux median melanopic EDI, 2 readings
Log scale, with lines at 125 and 250. The sample has no occupant groups, so it maps by area only.

What reaches the daytime target

Generated sample data
  • Daylight-dominated9 positions

    9 of 9 reach 250

    9 250 or more: L1 5, L2 4

  • Electric + daylight27 positions

    19 of 27 reach 250

    19 250 or more: Ground 8, L1 5, L2 67 125 to 250: Ground 4, L1 1, L2 21 below 125: L1 1

  • Electric light alone12 positions

    0 of 12 reach 250

    4 125 to 250: Ground 2, L2 28 below 125: Ground 3, L1 4, L2 1

Every position, grouped by what lit it and split by result, with the floor each result came from.

05

Written summary for architect, clinical, and facilities teams

Kestrel Medical Centre: findings

Generated sample data

237 lx

median melanopic EDI at positions not dominated by daylight

the daytime target is 250

0 of 12

positions on electric light alone reach 250

the highest was 219 lx

9 of 48

positions are daylight-dominated

median 702 lx melanopic EDI

620 lx

needed at the eye under the LED 2700 K lighting to reach 250

sample median under it: 160 lx

Executive summary, abridged

This sample covers 48 generated readings across 3 floors and 20 zones of Kestrel Medical Centre, set out as one morning from 08:45 to 11:51, lights and blinds as found. Rated against a daytime target of 250 lx melanopic EDI, the building splits in two. Positions near the glazing meet the target on daylight. Positions lit by electric light alone fall short: none of the 12 reached it, with a median of 108 lx.

  1. 01

    Daylight does the work, and it stops a few metres from the glass.

    The 9 daylight-dominated positions had a median of 702 lx melanopic EDI, and the lowest of them was 342 lx: all at or above the daytime target. Exam rooms with a window had a median of 406 lx; interior exam rooms, 194 lx. In the admin office, desks in the window row had a median of 804 lx; desks on the core side, 132 lx. Of the positions lit by electric light alone, none of the 12 reached 250 lx; their median was 108 lx and the highest 219 lx.

  2. 02

    The installed sources carry little of the light that sets the body clock.

    Per lux, the electric sources delivered a median melanopic DER of 0.50, against 0.82 at daylight-dominated positions. To reach 250 lx melanopic EDI, the LED 2700 K lighting would need about 620 lx at the eye, 3.9 times the 160 lx recorded under it in the sample. An illuminance reading on its own would not show the difference, so the report gives lux and melanopic EDI side by side.

  3. 03

    The refurbished fit-out does better, and still falls short.

    On electric light alone, the 4000 K LED panels gave a median of 196 lx melanopic EDI at 351 lx, against 111 lx at 224 lx under the original fluorescent. On Level 2, none of the 3 electric-only positions reached 250 lx; on Level 1, none of the 4. The 8 readings in rooms with no daylight (Exam room G.3, Records & storage, Staff break room and Exam room 2.3) had a median of 144 lx and a highest of 219 lx.

Abridged: the headline numbers, the executive summary and three findings. Every number is read from the sample data.

What the measurement becomes

The assessment tells you where the building stands. Step 02 turns it into a decision: every realistic alternative modeled side by side, priced in the same units. See the comparison report →

Put the evidence on the table.

An independent assessment and a Facility Report your board can act on, before the specification is written.