Lighting Assessment
Turn your building’s light into a case your board can defend.
Independent experts measure the light your occupants actually live under, then translate it into the financial language that survives value engineering. We don’t sell fixtures. The assessment shows exactly where your light falls short; the next step puts a number on what that’s costing you.
Sample readout
Generated sample dataWaiting area by the window
#36 · Waiting area · Level 2
664lx mEDI
250 or more
Waiting area by the window: 664 lux melanopic EDI, 250+ mEDI, meets daytime target. Across the building, 20 of 48 positions are below the 250 lux daytime target.
Why Earthlight
Independent lighting experts, translating research into financial intelligence
Experienced
Over a decade translating circadian lighting science into the financial language that owners, operators, and boards actually use to decide.
Research-backed
Our models are built on the most credible peer-reviewed lighting science and the recognized measurement standards the field has converged on.
Product-neutral
We're paid for the analysis, not the fixtures. The assessment is finished before any vendor is in the room, and when we help you source against it, a proposal clears on the performance it delivers, whoever it comes from.
The engagement
One visit, an evidence-grade baseline
Everything downstream (the comparison report, the pilot, the purchase) is built on this measurement. Experts on site, documenting the light your building actually delivers, in the same units the standards are written in.
The visit
Light Environment Assessment
An on-site visit. We document your building's actual light: lux levels, color temperature, spectra, the timing of light exposure across the occupied day, and the quality of darkness at night. We map circadian-disruption risk area by area, population by population.
You receive a written summary of where the building stands, in language your architect, clinical lead, and facilities team can all read.
What you receive
- Current lux levels and spectral readingsSee sample ↓
- Timing of light exposure across the occupied day
- Darkness quality at night
- Circadian-disruption risk mapped by area and populationSee sample ↓
- Written summary for architect, clinical, and facilities teamsSee sample ↓
What that looks like
The deliverables, shown on a sample building
Everything tagged Generated sample data below is from our sample report for Kestrel Medical Centre, an invented 3-floor outpatient clinic with generated readings at 48 positions, laid out as one morning’s walk-through. Client reports stay confidential, so this is the one we show.
01
Current lux levels and spectral readings
Every position, on the plan
Generated sample dataSelect a point to see what the meter recorded there.
- Below 125
- 125 to 250
- 250 or more
- Hollow: daylight-dominated
- Glazing
- Direction the meter faced
mEDI in lx. North wall is a party wall; glazing on the south, west and east.
Reading 15 of 48
Exam room G.3
Clinician's desk against the back wall
Surveyor’s note. In a real assessment, the site photo taken with the reading sits beside it.
Melanopic EDI
125 to 250 mEDI
174lx
- Illuminance
- 352 lx
- Melanopic DER
- 0.49
- Colour temperature
- 3,477 K
- CRI Ra / R9
- 80 / -38
- TM-30 Rf / Rg
- 80 / 96
- Daylight share
- 0%
Fluorescent (tri-phosphor) · Fluorescent 3500 K · Ground floor · 09:39
Hover, tap or use the arrow keys on the chart to read any wavelength.
All 48 positions against 125 and 250
Generated sample dataMelanopic EDI (lx), log scale · reading number, in survey order
- Below 125 mEDI
- 125 to 250 mEDI
- 250+ mEDI, meets daytime target
- Hollow: daylight-dominated
Colour temperature and circadian signal per lux
Generated sample dataIlluminance needed at the eye to reach 250 lx melanopic EDI, at each source’s median DER
- LED 2700 KDER 0.40620 lx
- Fluorescent 3500 KDER 0.50500 lx
- LED 4000 KDER 0.56450 lx
- Daylight-dominatedDER 0.82300 lx
Unlabelled points mix electric light and daylight. Shapes show each reading’s mEDI band, as on the map.
Old fittings and new
Generated sample dataLED 2700 K
Level 1 · 2 positions
64 lx mEDI
at 160 lx · DER 0.40Fluorescent 3500 K
Original fit-out · Ground floor, Level 1 · 7 positions
111 lx mEDI
at 224 lx · DER 0.50LED 4000 K
Refurbished fit-out · Level 2 · 3 positions
196 lx mEDI
at 351 lx · DER 0.56
Melanopic EDI (lx), linear · lines at 125 and 250 · bar: median
What lit each position
Generated sample data- Mixed: LED + daylight19 readingsmedian 385 lx
- Daylight-dominated9 readingsmedian 702 lx
- Mixed: Fluorescent + daylight8 readingsmedian 290 lx
- Fluorescent (tri-phosphor)7 readingsmedian 111 lx
- LED5 readingsmedian 104 lx
02
Timing of light exposure across the occupied day
Not in this sample: it is a single morning walk-through, with no readings later in the day or after dark.
03
Darkness quality at night
Not in this sample: it is a single morning walk-through, with no readings later in the day or after dark.
04
Circadian-disruption risk mapped by area and population
Median melanopic EDI, zone by zone
Generated sample dataGround floor
- Procedure room535 lux median melanopic EDI, 3 readings
- Exam room G.1340 lux median melanopic EDI, 2 readings
- Exam room G.2336 lux median melanopic EDI, 2 readings
- Reception & waiting200 lux median melanopic EDI, 4 readings
- Exam room G.3184 lux median melanopic EDI, 2 readings
- Records & storage105 lux median melanopic EDI, 2 readings
- Ground corridor96 lux median melanopic EDI, 2 readings
Level 1
- Admin office, window side804 lux median melanopic EDI, 4 readings
- Consult room 1.1395 lux median melanopic EDI, 2 readings
- Consult room 1.2342 lux median melanopic EDI, 2 readings
- Level 1 corridor214 lux median melanopic EDI, 2 readings
- Admin office, core side132 lux median melanopic EDI, 4 readings
- Staff break room64 lux median melanopic EDI, 2 readings
Level 2
- Nurse station882 lux median melanopic EDI, 2 readings
- Waiting area664 lux median melanopic EDI, 3 readings
- Exam room 2.1568 lux median melanopic EDI, 2 readings
- Exam room 2.2528 lux median melanopic EDI, 2 readings
- Consult room 2.1262 lux median melanopic EDI, 2 readings
- Exam room 2.3208 lux median melanopic EDI, 2 readings
- Level 2 corridor117 lux median melanopic EDI, 2 readings
What reaches the daytime target
Generated sample dataDaylight-dominated9 positions
9 of 9 reach 250
99 250 or more: L1 5, L2 4
Electric + daylight27 positions
19 of 27 reach 250
197119 250 or more: Ground 8, L1 5, L2 67 125 to 250: Ground 4, L1 1, L2 21 below 125: L1 1
Electric light alone12 positions
0 of 12 reach 250
484 125 to 250: Ground 2, L2 28 below 125: Ground 3, L1 4, L2 1
05
Written summary for architect, clinical, and facilities teams
Kestrel Medical Centre: findings
Generated sample data237 lx
median melanopic EDI at positions not dominated by daylight
the daytime target is 250
0 of 12
positions on electric light alone reach 250
the highest was 219 lx
9 of 48
positions are daylight-dominated
median 702 lx melanopic EDI
620 lx
needed at the eye under the LED 2700 K lighting to reach 250
sample median under it: 160 lx
Executive summary, abridged
This sample covers 48 generated readings across 3 floors and 20 zones of Kestrel Medical Centre, set out as one morning from 08:45 to 11:51, lights and blinds as found. Rated against a daytime target of 250 lx melanopic EDI, the building splits in two. Positions near the glazing meet the target on daylight. Positions lit by electric light alone fall short: none of the 12 reached it, with a median of 108 lx.
01
Daylight does the work, and it stops a few metres from the glass.
The 9 daylight-dominated positions had a median of 702 lx melanopic EDI, and the lowest of them was 342 lx: all at or above the daytime target. Exam rooms with a window had a median of 406 lx; interior exam rooms, 194 lx. In the admin office, desks in the window row had a median of 804 lx; desks on the core side, 132 lx. Of the positions lit by electric light alone, none of the 12 reached 250 lx; their median was 108 lx and the highest 219 lx.
02
The installed sources carry little of the light that sets the body clock.
Per lux, the electric sources delivered a median melanopic DER of 0.50, against 0.82 at daylight-dominated positions. To reach 250 lx melanopic EDI, the LED 2700 K lighting would need about 620 lx at the eye, 3.9 times the 160 lx recorded under it in the sample. An illuminance reading on its own would not show the difference, so the report gives lux and melanopic EDI side by side.
03
The refurbished fit-out does better, and still falls short.
On electric light alone, the 4000 K LED panels gave a median of 196 lx melanopic EDI at 351 lx, against 111 lx at 224 lx under the original fluorescent. On Level 2, none of the 3 electric-only positions reached 250 lx; on Level 1, none of the 4. The 8 readings in rooms with no daylight (Exam room G.3, Records & storage, Staff break room and Exam room 2.3) had a median of 144 lx and a highest of 219 lx.
What the measurement becomes
The assessment tells you where the building stands. Step 02 turns it into a decision: every realistic alternative modeled side by side, priced in the same units. See the comparison report →
Put the evidence on the table.
An independent assessment and a Facility Report your board can act on, before the specification is written.